Reference Guide

The following command deletes security key for controller:
racadm storage deletesecuritykey:RAID.Integrated.1-1
To convert the physical disk drive and assign hotspare.
The following command converts the specified non-storage physical disk drive to a storage capable physical disk drive:
racadm storage converttoraid:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1
The following command converts the specified physical disk drive to a non-storage physical disk drive:
racadm storage converttononraid:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1
The following command assigns or unassigns a global or dedicated Hot spare:
racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -assign
no
racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -assign
yes -type ghs
racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -assign
yes -type dhs -vdkey:Disk.Virtual.0:RAID.Integrated.1-1
To reset, clear, and import the storage configuration to the controller.
The following command imports the current foreign configuration from the controller:
racadm storage importconfig:RAID.Integrated.1-1
The following command deletes all virtual disks and un-assign hot spare from the associated controller:
racadm storage resetconfig:RAID.Integrated.1-1
The following command clears the current foreign configuration from the controller:
racadm storage clearconfig:RAID.Integrated.1-1
NOTE: After a resetconfig or clearconfig operation, the data cannot be reversed.
To blink or unblink the PCIeSSD device.
The following command blinks the specified PCIeSSD device:
racadm storage blink:Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3
STOR095 : Storage operation is successfully completed.
The following command unblinks the specified PCIeSSD device:
racadm storage unblink:Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3
STOR095 : Storage operation is successfully completed.
To prepare the specified PCIeSSD device for removal, run the following command:
racadm storage preparetoremove: Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3
STOR089 : Successfully accepted the storage configuration operation.
To apply the configuration operation, create a configuration job with --realtime option.
To create the required commit jobs, run the jobqueue command.
For more information about the jobqueue command, enter the RACADM command "racadm help
jobqueue”
To perform a secure erase operation on the specified PCIeSSD device, run the following command:
racadm storage secureerase: Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3
RAC1040 : Successfully accepted the storage configuration operation.
To apply the configuration operation, create a configuration job, and then restart the
server.
To create the required commit and reboot jobs, run the jobqueue command.
For more information about the jobqueue command, enter the RACADM command "racadm help
jobqueue”
swinventory
Description
Displays the list of software objects and associated properties installed on a server.
89