Reference Guide

Valid Severity values are:
Critical
Warning
Info
Valid examples of alert queries are:
idrac.alert.all
idrac.alert.audit
idrac.alert.audit.lic
idrac.alert.audit.warning
idrac.alert.audit.lic.critical
Input
get — Displays the list of eventfilter settings.
set — Configures the actions and notifications for a given eventfilter configuration.
-i — Message ID for which the simulation is needed.
-c — Alert category of the specific event filter.
-a — The action that must be invoked when the event occurs. Valid values are none, powercycle,
power off, or systemreset.
-n — The notification is sent when the event occurs. Valid values are all, snmp, ipmi, ws-events,
oslog, email, remotesyslog or none. You can append multiple notifications separated by a comma.
You cannot enter the values all or none with other notifications. If incorrect notification is specified
along with other valid notifications, the valid and invalid notification set is failed.
-r — Event generation interval. This option is applicable only to the temperature statistics subcategory
tmps. You can use this option as a stand-alone or with -n and -a.
NOTE: If both event generation interval and notifications are configured and there is an error while
configuring the notifications, the event generation interval is not set. The valid values are 0–365. 0
disables the event generation.
Example
Display all available event filter configurations:
racadm eventfilters get -c idrac.alert.all
Display eventfilter configurations for a specific category. For example, audit:
racadm eventfilters get -c idrac.alert.audit
Display eventfilter configurations for a specific subcategory. For example, licensing under the audit
category:
racadm eventfilters get -c idrac.alert.audit.lic
Display eventfilter configurations for a specific severity. For example, warning under the audit category:
racadm eventfilters get -c idrac.alert.audit.warning
Display eventfilter configurations for a specific severity and subcategory. For example, a severity of
warning in the subcategory licensing under audit category:
racadm eventfilters get -c idrac.alert.audit.lic.warning
Clear all available alert settings:
racadm eventfilters set -c idrac.alert.all -a none -n none
Configure using severity as a parameter. For example, all informational events in storage category are
assigned power off as action, and email and snmp as notifications:
racadm eventfilters set -c idrac.alert.storage.info -a poweroff -n
email,snmp
Configure using subcategory as a parameter. For example, all configurations under the licensing
subcategory in the audit category are assigned power off as action and all notifications are enabled:
racadm eventfilters set -c idrac.alert.audit.lic -a poweroff -n all
Configure using subcategory and severity as parameters. For example, all information events under the
licensing subcategory in the audit category are assigned power off as action and all notifications are
disabled:
racadm eventfilters set -c idrac.alert.audit.lic.info -a poweroff -n none