Reference Guide

System.Backplane
The objects in this group manage the backplane.
System.Backplane.BackplaneBusMode (Read Only)
Description Indicates the backplane Serial General Purpose Input or Output (SGPIO) mode.
Legal Values
0 — Unknown
1 — I2C
2 — SGPIO
Default Value 1 — I2C
Write Privilege
Configure iDRAC
License Required
iDRAC Express or iDRAC Enterprise
Dependency None
System.ChassisControl
The objects in this group are applicable only to modular chassis such as Dell PowerEdge M1000e. To control the chassis related
events, use this group.
System.ChassisControl.ChassisManagementMonitoring (Read or Write)
Description
Enables or disables the event forwarding from CMC.
Legal Values
0 — Disabled
1 — Enabled
Default value 1 — Enabled
Write Privilege Server Control
License
Required
Base
Dependency ChassisMangamentAt server object.
System.ChassisInfo
The objects in this group are applicable only to modular chassis such as Dell PowerEdge M1000e. To obtain the chassis-specific
information, use this group.
System.ChassisInfo.Model (Read Only)
Description
Indicates the LCD string the user modifies.
Legal Values String of up to 62 ASCII characters
Default Value None
Write privilege Not Applicable
License Required Not Applicable
Dependency None
164