Reference Guide

cfgNetTuningNicMtu (Read or Write)
Description
Indicated the maximum size of units in bytes transmitted by NIC.
Legal Values
576–1500
Default
1500
cfgSensorRedundancy
This group is used to set the power supply redundancy.
The following sections provide information about the objects in the cfgSensorRedundancy group.
This group is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers.
cfgSensorRedundancyIndex (Read Only)
Description
Specifies index for the sensor redundancy group being read. Only power supply redundancy is supported.
Legal Values
1
Default
None
cfgSensorRedundancyPolicy (Read or Write)
Description
Sets the power supply redundancy policy.
Legal Values
2 — N/A, for systems that are not supported
3 — Non Redundant
4–1+1 Redundant
4–2+1 Redundant
16–2+2 Redundant
Default
Any legal value at that particular execution instance.
cfgSensorRedundancyCapabilities (Read Only)
Description
Returns the redundancy capabilities in the form of a bitmask. This bitmask allows the user to know which
values can be set for cfgSensorRedundancyPolicy.
Legal Values
A bit mask. More than 1 bit can be set at a time to indicate multiple redundancy support.
0- N/A, for systems that are not supported
1- Non-Redundant
2- 1+1 — Redundant
4- 2+1 — Redundant
8- 2+2 — Redundant
Default
0
156