Reference Guide
Default
1
cfgIpmiSerialLineEdit (Read or Write)
Description
Enables or disables line editing on the IPMI serial interface.
Legal Values
• 0(FALSE)
• 1(TRUE)
Default
1
cfgIpmiSerialInputNewLineSequence (Read or Write)
Description
Specifies the input new line sequence specification for the IPMI serial interface.
Legal Values
• 1 — ENTER
• 2 — NULL
Default
1
cfgSmartCard
This group specifies properties used to support access to iDRAC using a smart card.
The following sections provide information about the objects in the cfgSmartCard group.
cfgSmartCardLogonEnable (Read or Write)
Description
To iDRAC using a smart card, enable or disable with Remote RACADM support for access.
NOTE: Enabling with remote RACADM is only applicable for iDRAC on Rack and Tower Servers.
Legal Values
• 0 (Disabled)
• 1 (Enabled)
• 2 (Enabled with Remote RACADM) — It is not applicable for iDRAC Enterprise on Blade Servers.
Default
0
cfgSmartCardCRLEnable (Read or Write)
Description
Enables or disables the Certificate Revocation List (CRL).
This object is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade
Servers.
Legal Values
• 1 (TRUE)
• 0 (FALSE)
Default
0
cfgNetTuning
This group enables users to configure the advanced network interface parameters for the RAC NIC. When configured, the updated
settings may take up to a minute to become active.
154