Reference Guide

1 — Absent
2 — Failure
3 — Predictive failure
Default 0 — Present
cfgServerPowerSupplyFwVer (Read Only)
Description
Displays the firmware version of the PSU, in the format x.xx.xxx.
Legal Values
A string up to 8 characters.
Default
Null
cfgServerPowerSupplyCurrentDraw (Read Only)
Description
Displays the instantaneous current consumption in 0.1 amps.
Legal Values
A string of up to 32 characters.
Default
0
cfgServerPowerSupplyType
Description
Displays whether the power supply is AC or DC.
Legal Values
A string of up to 32 characters.
Default
0
cfgIPv6LanNetworking
This group is used to configure the IPv6 over LAN networking capabilities.
Use this object with the config or getconfig subcommands.
NOTE: To apply this setting, use the -m option.
The following sections provide information about the objects in the cfgIPv6LanNetworking group.
cfgIPv6Enable (Read or Write)
Description
Enables or disables iDRAC IPv6 stack.
Legal Values
1 (TRUE)
0 (FALSE)
Default
0
cfgIPv6Address1 (Read or Write)
Description
Specifies iDRAC IPv6 address.
Legal Values
String representing a valid IPv6 entry.
Default
:
146