Reference Guide

cfgSerialCom2RedirEnable (Read or Write)
Description
Enables or disables the console for COM 2-port redirection.
The cfgSerialCom2RedirEnable object property is applicable only for iDRAC on Rack and Tower
Servers.
Legal Values
1 (TRUE)
0 (FALSE)
Default
1
cfgSerialHistorySize (Read or Write)
Description
Specifies the maximum size of the serial history buffer.
Legal Values
0–8192
Default
8192
cfgSerialSshEnable (Read or Write)
Description
Enables or disables the secure shell (SSH) interface.
Legal Values
1 (TRUE)
0 (FALSE)
Default
1
Example
racadm getconfig -g cfgSerial
cfgSerialBaudRate=115200
cfgSerialConsoleEnable=1
cfgSerialConsoleQuitKey=^\
cfgSerialConsoleIdleTimeout=1800
cfgSerialConsoleNoAuth=0
cfgSerialConsoleCommand=
cfgSerialConsoleColumns=0
cfgSerialHistorySize=8192
cfgSerialTelnetEnable=0
cfgSerialSshEnable=1
cfgSerialTelnetEnable (Read or Write)
Description
Enables or disables the Telnet console interface.
Legal Values
1 (TRUE)
0 (FALSE)
Default
0
cfgOobSnmp
This group contains parameters to configure the SNMP agent and trap capabilities of iDRAC. One instance of the group is allowed.
The CMC SNMP agent supports the standard RFC1213 mib-2 and the Dell enterprise-specific the MIB.
This group is not applicable for iDRAC on Rack and Tower Servers.
117