API Guide

HTTP Method Type Description URI Metadata Reference
GET Get Event Service detailed
information
/redfish/v1/EventService EventService.xml
POST Register an event notification
receiver
/redfish/v1/EventService/Subscriptions EventDestination.xml
DELETE Remove a subscription /redfish/v1/EventService/
Subscriptions /<Subscription ID>
EventService.xml
PowerEdge FX2/FX2s Chassis Management using iDRAC Redfish
On a PowerEdge FX2/FX2s chassis, iDRAC can monitor and manage chassis components such as fans, power supplies, and so on.
Redfish service provides information about chassis components when Chassis Management and Monitoring is set to Enabled on
iDRAC. This setting allows you to monitor and manage the chassis even if the CMC is not on the network. On an FX2/FX2s CMC,
ensure that the Chassis Management at Server setting is set to Monitor or Manage and Monitor. While this feature is enabled,
iDRAC also generates Redfish notifications for chassis events.
Configuring Chassis Management and Monitoring using iDRAC web interface
1. In iDRAC web interface, click Overview iDRAC SettingsCMC.
2. Under Chassis ManagementCapability from iDRAC at the Server section, select the Enabled check box. To disable the
service, clear the check box.
Configuring Chassis Management and Monitoring using iDRAC RACADM
To configure the chassis management and monitoring using RACADM, type
racadm set system.chassiscontrol.chassismanagementmonitoring Enabled
For more information on Chassis Management and Monitoring, see the iDRAC User’s Guide available at dell.com/idracmanuals.