Users Guide

Table Of Contents
Related concepts
Inventorying and monitoring storage devices on page 195
Viewing system inventory on page 99
Updating device firmware on page 62
Monitoring predictive failure analysis on drives on page 211
Blinking or unblinking component LEDs on page 222
Monitoring predictive failure analysis on drives
Storage management supports Self Monitoring Analysis and Reporting Technology (SMART) on physical disks that are SMART-
enabled.
SMART performs predictive failure analysis on each disk and sends alerts if a disk failure is predicted. The controllers check
physical disks for failure predictions and, if found, pass this information to iDRAC. iDRAC immediately logs an alert.
Controller operations in non-RAID (HBA) mode
If the controller is in non-RAID mode (HBA mode), then:
Virtual disks or hot spares are not available.
Security state of the controller is disabled.
All physical disks are in non-RAID mode.
You can perform the following operations if the controller is in non-RAID mode:
Blink/unblink the physical disk.
Configure all properties including the following:
Load balanced mode
Check consistency mode
Patrol read mode
Copyback mode
Controller boot mode
Enhanced auto import foreign configuration
Rebuild rate
Check consistency rate
Reconstruct rate
BGI rate
Enclosure or backplane mode
Patrol read unconfigured areas
View all properties that are applicable to a RAID controller expect for virtual disks.
Clear foreign configuration
NOTE: If an operation is not supported in non-RAID mode, an error message is displayed.
You cannot monitor the enclosure temperature probes, fans, and power supplies when the controller is in non-RAID mode.
Running RAID configuration jobs on multiple storage controllers
While performing operations on more than two storage controllers from any supported iDRAC interface, make sure to:
Run the jobs on each controller individually. Wait for each job to complete before starting the configuration and job creation
on the next controller.
Schedule multiple jobs to run at a later time using the scheduling options.
Managing PCIe SSDs
Peripheral Component Interconnect Express (PCIe) solid-state device (SSD) is a high-performance storage device designed for
solutions requiring low latency, high Input Output Operations per Second (IOPS), and enterprise class storage reliability and
serviceability. The PCIe SSD is designed based on Single Level Cell (SLC) and Multi-Level Cell (MLC) NAND flash technology
Managing storage devices
211