Users Guide
PERC Capability CEM conguration Capable Controller
(PERC 9.1 or later)
CEM conguration Non-capable
Controller (PERC 9.0 and lower)
Real-time If there is no existing pending or
scheduled jobs for the controller, then
conguration is applied.
If there are pending or scheduled jobs for
that controller, then the jobs have to be
cleared or you must wait for the jobs to be
completed before applying the
conguration at run-time. Run-time or
real-time means, a reboot is not required.
Conguration is applied. An error message
is displayed. Job creation is not successful
and you cannot create real-time jobs using
Web interface.
Staged If all the set operations are staged, the
conguration is staged and applied after
reboot or it is applied at real-time.
Conguration is applied after reboot
Related links
Understanding RAID concepts
Inventorying and monitoring storage devices
Viewing storage device topology
Managing controllers
Managing physical disks
Managing enclosures or backplanes
Managing PCIe SSDs
Managing virtual disks
Blinking or unblinking component LEDs
Supported controllers
Supported enclosures
Summary of supported features for storage devices
Understanding RAID concepts
Storage Management uses the Redundant Array of Independent Disks (RAID) technology to provide Storage Management capability.
Understanding Storage Management requires an understanding of RAID concepts, as well as some familiarity with how the RAID
controllers and operating system view disk space on your system.
What is RAID?
RAID is a technology for managing the storage of data on the physical disks that reside or are attached to the system. A key aspect
of RAID is the ability to span physical disks so that the combined storage capacity of multiple physical disks can be treated as a
single, extended disk space. Another key aspect of RAID is the ability to maintain redundant data which can be used to restore data
in the event of a disk failure. RAID uses dierent techniques, such as striping, mirroring, and parity, to store and reconstruct data.
There are dierent RAID levels that use dierent methods for storing and reconstructing data. The RAID levels have dierent
characteristics in terms of read/write performance, data protection, and storage capacity. Not all RAID levels maintain redundant
data, which means for some RAID levels lost data cannot be restored. The RAID level you choose depends on whether your priority is
performance, protection, or storage capacity.
NOTE: The RAID Advisory Board (RAB) denes the specications used to implement RAID. Although RAB denes the
RAID levels, commercial implementation of RAID levels by dierent vendors may vary from the actual RAID
specications. An implementation of a particular vendor may aect the read and write performance and the degree of
data redundancy.
Hardware and software RAID
RAID can be implemented with either hardware or software. A system using hardware RAID has a RAID controller that implements
the RAID levels and processes data reads and writes to the physical disks. When using software RAID provided by the operating
182