Users Guide

Conguring WS Eventing
The WS Eventing protocol is used for a client service (subscriber) to register interest (subscription) with a server (event source) for
receiving messages containing the server events (notications or event messages). Clients interested in receiving the WS Eventing
messages can subscribe with iDRAC and receive Lifecycle Controller job related events.
The steps required to congure WS Eventing feature to receive WS Eventing messages for changes related to Lifecycle Controller
jobs are described in the Web service Eventing Support for iDRAC 1.30.30 specication document. In addition to this specication,
see the DSP0226 (DMTF WS Management Specication), Section 10 Notications (Eventing) document for the complete
information on the WS Eventing protocol. The Lifecycle Controller related jobs are described in the DCIM Job Control Prole
document.
Conguring Redsh Eventing
The Redsh eventing protocol is used for a client service (subscriber) to register interest (subscription) with a server (event source)
for receiving messages containing the Redsh events (notications or event messages). Clients interested in receiving the Redsh
eventing messages can subscribe with iDRAC and receive Lifecycle Controller job related events.
Monitoring chassis events
On the PowerEdge FX2/FX2s chassis, you can enable the Chassis Management and Monitoring setting in iDRAC to perform
chassis management and monitoring tasks such as monitoring chassis components, conguring alerts, using iDRAC RACADM to
pass CMC RACADM commands, and updating the chassis management rmware. This setting allows you to manage the servers in
the chassis even if the CMC is not on the network. You can set the value to Disabled to forward the chassis events. By default, this
setting is set as Enabled.
NOTE: For this setting to take eect, you must ensure that in CMC, the Chassis Management at Server setting must be
set to Monitor or Manage and Monitor.
When the Chassis Management and Monitoring option is set to Enabled, iDRAC generates and logs chassis events. The events
generated are integrated into the iDRAC event subsystem and alerts are generated similar to the rest of the events.
CMC also forwards the events generated to iDRAC. In case the iDRAC on the server is not functional, CMC queues the rst 16
events and logs the rest in the CMC log. These 16 events are sent to iDRAC as soon as Chassis monitoring is set to enabled.
In instances where iDRAC detects that a required CMC functionality is absent, a warning message is displayed informing you that
certain features may not be functional without a CMC rmware upgrade.
Monitoring chassis events using the iDRAC web interface
To monitor chassis events using the iDRAC web interface, perform the following steps:
NOTE: This section appears only for PowerEdge FX2/FX2s chassis and if Chassis Management at Server mode is set to
Monitor or Manage and Monitor in CMC.
1. On the CMC interface, click Chassis OverviewSetupGeneral.
2. From the Chassis Management at Server Mode drop-down menu, select Manage and Monitor, and click Apply.
3. Launch the iDRAC web interface, click OverviewiDRAC SettingsCMC.
4. Under the Chassis Management at Server section, ensure that Capability from iDRAC drop-down box is set to Enabled.
Monitoring chassis events using RACADM
This setting is applicable only for PowerEdge FX2/FX2s servers and if Chassis Management at Server mode is set to Monitor or
Manage and Monitor in CMC.
159