Reference Guide

Table Of Contents
g Specifies the size in gigabytes
t Specifies the size in terabytes
-sc Number of spans in a virtual disk (required for multi-span RAID level).
NOTE:
For PERC9, if the value of controller.SupportRAID10UnevenSpans is supported, you
can enter only 0 for this option while creating RAID level 10. The created RAID10 virtual disk will
display the spandepth as 1 (default).
For other controllers:
The default value for multi-span RAID levels is 2 and for basic RAID level is 1.
For hybrid RAID levels such as RAID10, RAID50, and RAID60, this option is mandatory.
The value for-sc option can be 0 only for RAID10.
-T10PIEnable Creates a virtual disk with protection information.
-key <Key id> Specifies the key id.
-passwd <passphrase> Specifies the passphrase.
-newpasswd <passphrase> Specifies the new passphrase.
-assign {yes | no} Assigns or unassigns the disk as a hotspare.
-type { ghs | dhs} Assigns a global or dedicated hotspare.
-vdkey:<VD FQDD> Assigns the dedicated hotspare to the specified virtual disk. This option is
required for dedicated hotspare.
-state <start|stop> start value starts a patrol read operation. stop value stops a running
patrol read operation.
NOTE: To start the operation, the Controller.PatrolReadMode must be in Manual mode.
-speed Specifies the initialization of the Virtual disk.
fast Performs fast initialization.
full Performs slow initialization.
blink: <FQDD> or unblink: <FQDD> <FQDD> can be physical disk drives, virtual disks, or
PCIeSSD.
<PCIeSSD FQDD> Specifies the PCIeSSD FQDD.
<PCIeSSD controller|enclosure FQDD> Specifies the PCIeSSD controller or enclosure
FQDD.
preparetoremove Specifies the PCIeSSD drive to prepare for removal.
NOTE: Ensure that ISM is installed and running to perform the preparetoremove operation.
secureerase Specifies the PCIeSSD drive to perform the secure erase operation.
Example
Inventory
To view the help details for get command, run the following command:
racadm>>storage help get
racadm storage help get
Storage monitoring and inventory of hardware RAID connected to the system.
Usage :
racadm storage get status
racadm storage help <Object type I/II>
racadm storage get <Object type I>
racadm storage get <Object type I> -current
racadm storage get <Object type I> -pending
racadm storage get <Object type I> -o
racadm storage get <Object type I> -o -p <property names separated by comma>
racadm storage get <Object type I>:<FQDD's of Object type I separated by comma> -p
<property names separated by comma>
racadm storage get <Object type I>:<FQDD's of Object type I separated by comma>
racadm storage get <Object type II> --refkey <reference keys separated by comma>
racadm storage get <Object type II> --refkey <reference keys separated by comma> -o
racadm storage get <Object type II> --refkey <reference keys separated by comma> -o
-p <property names separated by comma>
86
RACADM Subcommand Details