Release Notes

name of the Update Package is incorrect.
Only Windows operating system can be deployed on systems with software RAID controller.
Using Platform Update, you cannot update components such as Complex Programmable Logic Device,
Backplane, and Physical Disk. However, the View Current Versions table displays these components.
The SATA drives and their firmware version are not displayed on the View Current Versions page of
Platform Update. To view the SATA drives and their firmware information, use OpenManage Server
Administrator or OpenManage Storage Services.
The PCIe SSD drives and their firmware versions are not displayed on the View Current Versions page of
Platform Update.
Collect System Inventory On Reboot (CSIOR) must to be run before enum is successful.
BCM57xx /BCM57xxx updates Limitations - When you update the firmware on Broadcom NetXterme I
and QLogic BCM57xx/BCM57xxx (previously known as Broadcom NetXtreme II) Ethernet adapters, you
may notice failure or incorrect rollback version displayed based on the firmware update used. This
behavior occurs because separate firmware update packages are provided for the Broadcom NetXtreme
adapters and QLogic BCM57xx and BCM57xxx adapters due to the acquisition of the Broadcom NetXtreme
II cards by QLogic. Prior to the acquisition, a common shared firmware update package was provided.
Limitations on updating firmware on Broadcom and QLogic adapters using iDRAC interfaces such as WS-
MAN, RACADM, iDRAC GUI, and Lifecycle Controller UI:
o Rollback of Broadcom NetXtreme I to 7.10.X and QLogic BCM57xx and BCM57xxx Ethernet
adapters to 7.12.X from the iDRAC GUI may result in failure of rollback to 7.12.X.
o Updating Broadcom NetXtreme I to 7.10.X and QLogic BCM57xx and BCM57xxx Ethernet
adapters to 7.12.7 results in updating both Broadcom NetXtreme I and QLogic BCM57xx and
BCM57xxx to 7.10.X.
o Downgrading to version 7.10.X on a system with Broadcom NetXtreme I 7.10.X and QLogic
BCM57xx and BCM57xxx Ethernet adapters 7.12.X results in displaying the QLogic BCM57xx and
BCM57xxx Ethernet adapters rollback version as NULL even though it is updated to 7.10.X.
o Repository updates to Broadcom NetXtreme I and QLogic BCM57xx and BCM57xxx Ethernet
adapters works only with iDRAC version 2.10.10.10 or later.
o QLogic BCM57xx and BCM57xxx adapters may be displayed as Broadcom or QLogic depending
on the interface used such RACADM or WS-MAN.
Part replacement feature is not supported for PCIe SSD devices.
Security Fixes
Multiple security updates.
Security Important Notes
None.
Security Known Issues
None.
iDRAC Installation
Installation Instructions
From the Windows host operating system (managed node), run the Dell Update Package for Windows and
follow the instructions on the update wizard.