Release Notes
Versions
/
Systems
Affected
All LC–supported Dell PowerEdge servers.
Issue 9:
Description
The process of retrieving IPv6 address from the DHCP server with VLAN connection takes a few minutes.
Resolution
Wait for a few minutes and check the Network Settings page to view the assigned IPv6 address.
Versions
/
Systems
Affected
All LC–supported Dell PowerEdge servers.
LC GUI – Limitations
• Lifecycle Controller supports the following characters for user name and password:
o Alphabets (a-z, A-Z)
o Digits (0-9)
o Special characters (-, _, .)
• While updating iDRAC firmware using a tool other than Lifecycle Controller, Lifecycle Controller must not
be open, or running, because it results in an unknown behavior. Use Lifecycle Controller after the firmware
is successfully updated.
• If the iDRAC firmware update is interrupted for any reason, wait for 30 minutes before attempting another
firmware update.
• From Lifecycle Controller UI, only Windows operating system can be deployed by using software RAID
controller.
• Firmware update is supported only for LAN On Motherboards, Network Daughter Cards, and network
adapters from Broadcom, QLogic, and Intel, and some of the QLogic and Emulex fiber channel cards. For
the list of supported fiber channel cards, see Lifecycle Controller GUI v2.30.30.30 User’s Guide.
• After the CPLD firmware is updated on modular servers, on the View Current Versions page, under Firmware
update, the firmware update date is displayed as 2000-01-01, regardless of the actual update date. The
updated date and time is displayed on the basis of time zone that is configured on the server.
• Rollback is not supported for CPLD.
• On some modular systems, after a firmware update, the Lifecycle Log displays the date in the time stamp as
1999-12-31, instead of the date on which Firmware Update was performed.
• Some properties related to devices installed in PowerEdge VRTX system are not displayed while viewing the
current hardware inventory.
• Lifecycle Controller can import and view an iDRAC license, but it cannot export or delete the iDRAC license.
• The iSCSI offload feature can be enabled only on two of the available four ports. If the iSCSI offload attribute
is enabled on a card, and is replaced by another card whose iSCSI offload mode is also enabled on the other
two ports, an error is thrown. The firmware will not allow the attribute to be set, because it is already set on
the other two ports.
• Windows OS supports both the manual installation and unattended installation features. However, Lifecycle
Controller supports the unattended installation feature for Windows and RHEL-7 operating systems only.
• VLAN configuration is not supported on all vendor FC cards and the following Emulex cards:
o Emulex OneConnect OCe14102-U1-D 2-port PCIe 10GbE CNA
o Emulex OneConnect OCm14104-U1-D 4-port 10GbE rNDC CNA
o Emulex OneConnect OCm14102-U5-D 2-port 10GbE Mezz CNA
o Emulex OneConnect OCm14102-U4-D 2-port 10GbE bNDC CNA
o Emulex OneConnect OCe14102-N1-D 2-port PCIe 10GbE NIC
o Emulex OneConnect OCm14104-N1-D 4-port 10GbE rNDC NIC
o Emulex OneConnect OCm14102-N5-D 2-port 10GbE Mezz NIC