Release Notes

Issue 233773:
Description
After applying the Boot Identity profile on the PowerEdge M630 blade server with DX69G NDC card on
port 1, the WWN/MAC page displays the MAC Addresses under the Flexaddress tab only instead of
displaying in Remote assigned MAC Address tab.
Resolution
None.
Versions
/
Systems
Affected
Dell PowerEdge M1000e systems
Issue 237790:
Description
On a 12th generation of PowerEdge server with iDRAC7, the firmware version displays iDRAC8 instead of
iDRAC7.
Resolution
None.
Versions
/
Systems
Affected
Dell 12th generation of PowerEdge server with iDRAC7
Issue 258250:
Description
You may notice the following issues on the Dell 12th generation of PowerEdge servers with iDRAC
connected to the dedicated network port, if the Evaluation license has expired or after deleting the
Enterprise license:
iDRAC web interface fails to switch the NIC Selection option from
Dedicated
to
Shared
(default)
the system is inaccessible from remote RACADM and SSH to make changes
the system is blocked
Resolution
Before deleting the license, change the
Network Selection
option from
Dedicated
to
Shared
. To
access the
Network Selection
option, on the iDRAC web interface, click
iDRAC Settings->
Network-> NIC Selection
.
In case the license has expired, perform one of the following steps:
o Reboot the server, press F2 during POST, and set the
Network Selection
option to
Shared
.
o Install the local RACADM tool in the host server and execute the following commands to
switch the network selection to LOM:
To set to LOM1 racadm set idrac.nic.selection 2
To get NIC selection racadm get idrac.nic.selection.
For help on the command, type racadm help idrac.nic.selection
Versions
/
Systems
Affected
All Dell PowerEdge systems with iDRAC7.
Issue 253227:
Description
Occasionally, after changing NIC Selection, you may not be able to set NIC Failover.
Resolution
Reboot iDRAC or perform an AC power cycle to clear the issue.
Versions/ Systems
Affected
All Dell PowerEdge systems with iDRAC8 2.21.21.21