Release Notes
Issue 236311
:
Description
Persistence policy is not supported on ChassisSlot NIC devices.
Resolution
Reconfigure or clear the Virtual, Storage Initiator, or Target settings manually.
Version
/
Systems
Affected
All PowerEdge blade servers on PowerEdge FX2 with iDRAC8.
Issue 206438:
Description
The possible values for the WS-MAN IOI Persistence attributes are confusing to understand.
Example:
PossibleValues = None, WarmReset, ColdReset, WarmReset, ColdReset, ACPowerLoss, WarmReset,
ACPowerLoss, ColdReset, ACPowerLoss, WarmReset, ColdReset, ACPowerLoss
Resolution
Add the –format:pretty option in the WinRM command to display the output in an understandable format
Example:
<n1:PossibleValues>None</n1:PossibleValues>
<n1:PossibleValues>WarmReset</n1:PossibleValues>
<n1:PossibleValues>ColdReset</n1:PossibleValues>
<n1:PossibleValues>WarmReset, ColdReset</n1:PossibleValues>
Versions
/
Systems
Affected
All Dell PowerEdge systems with iDRAC8.
Issue 238583:
Description
On systems with iDRAC8, non-root user privileges are lost after installing and uninstalling a personality
module.
Resolution
Login using root credentials and modify the non-root users or reset iDRAC configurations to the default
setting.
Versions
/
Systems
Affected
All Dell PowerEdge systems with iDRAC8.
Issue 203881:
Description
iDRAC interfaces report the battery status as
Degraded
instead of
Battery Missing
when the battery is
unplugged and
Battery High Temp
when the battery temperature exceeds 70°C.
Resolution
None.
Versions
/
Systems
Affected
All Dell PowerEdge systems with iDRAC7 and iDRAC8 (PERC8 and PERC9).