Release Notes

While enumerating using WS-MAN, if you include more than 7 properties in the WQL/CQL query, the
select query does not return any result.
Resolution
The maximum number of properties that can be included in a WQL/CQL query using WS-MAN is 7.
Perform the filtering on the client system or make multiple calls each having not more than 7 properties.
Versions
/
Systems
Affected
All Dell PowerEdge systems with iDRAC8.
Issue 49:
Description
Scheduling an automatic update using the iDRAC GUI fails in case CSIOR is set to disabled.
Resolution
Use RACADM to schedule an automatic update job with CSIOR disabled or enable CSIOR and update
using the iDRAC GUI.
Versions
/
Systems
Affected
All Dell PowerEdge systems with iDRAC8.
Issue 50:
Description
The BIOS configuration job completes with errors when Virtualization Technology is set to
Enabled
or
Disabled
. All the settings are successfully applied, however, the job status displays an error.
Resolution
None.
Versions
/
Systems
Affected
All PowerEdge systems with iDRAC8.
Issue 51:
Description
On the Dell 12th generation PowerEdge servers flashed with iDRAC8, firmware update and configuration
operations including secure erase for Samsung NVMe PCIe SSDs using iDRAC interfaces, do not work.
Even though you can start these tasks using iDRAC interfaces, the tasks will eventually fail.
Resolution
Use other methods of firmware update and configuration using the operating system.
Versions
/
Systems
Affected
Dell 12th generation PowerEdge systems with iDRAC8.
Issue 52:
Description
Creating T10 PI capable virtual disks using T10 PI capable disk-drives from iDRAC GUI fails.
Resolution
Use RACADM, WS-MAN, or OMSS to create virtual disks with T10 PI capability.
Versions
/
Systems
Affected
All Dell PowerEdge systems with iDRAC8.