Release Notes
Issue 35:
Description
When you update the rebrand image from the iDRAC web interface, the system reboots and the
rebranded images are applied successfully. During POST, if you press <F10>, the Lifecycle Controller UI
starts to launch. The progress bar displays till 90% and then the system starts rebooting.
Resolution
After rebranding, do not access the Lifecycle Controller UI.
Versions
/
Systems
Affected
All Dell PowerEdge systems with iDRAC8.
Issue 36:
Description
If the number of physical or virtual disks selected for identification is more than 100, the blink or unblink
operation fails without displaying any message.
Resolution
Select less than 100 physical or virtual disks, or the required disk and retry the operation.
Versions
/
Systems
Affected
All Dell PowerEdge systems with iDRAC8.
Issue 37:
Description
Chassis slots mapped to the server are not visible using the WS-MAN DCIM_Slot class enumeration.
DCIM_slot class provides the server hardware information in terms of available and occupied slots where
devices can be added or removed respectively.
Resolution
None
Versions
/
Systems
Affected
All Dell Modular PowerEdge systems with iDRAC8.
Issue 38:
Description
While importing or replacing license files using Google Chrome or Microsoft Internet Explorer, the
operation fails for certain license files.
Resolution
Import or replace the license files using other supported browser(s) or using other interfaces such as
RACADM, Lifecycle Controller, and so on.
Versions
/
Systems
Affected
All Dell PowerEdge systems with iDRAC8.
Issue 39:
Description
When the physical drives connected to a PERC storage controller are in Non-RAID (or unitialized) state,
the size reported by the iDRAC interfaces (WS-MAN, RACADM, and iDRAC GUI) is slightly less than the
actual size of the drive.