Release Notes

Issue 30:
Description
When a passive backplane (that is not connected to PERC) is updated from the operating system, the
System Inventory
page in the iDRAC web interface does not display the updated version.
Resolution
Reset iDRAC using racadm racreset command.
Versions
/
Systems
Affected
All Dell PowerEdge systems with iDRAC8.
Issue 31:
Description
If you log in to the iDRAC8 web interface with Login and Config iDRAC privilege, then on the
Update and
Rollback
page, an additional
Firmware Settings
submenu appears.
Resolution
None
Versions
/
Systems
Affected
All Dell PowerEdge systems with iDRAC8.
Issue 32:
Description
On the
Network Devices
page, the Initiator and Storage Target Settings table overflows to the right if you
set the initiator name and chap ID value with more than 120 characters.
Resolution
Reduce the zoom level or use the scrollbar to view the entire data.
Versions
/
Systems
Affected
All Dell PowerEdge systems with iDRAC8.
Issue 33:
Description
URL string in iDRAC hardware inventory list displays incorrect https port number.
Resolution
IP URL in hardware inventory output always displays the standard https port number, that is, 443.
Versions
/
Systems
Affected
All Dell PowerEdge systems with iDRAC8.
Issue 34:
Description
Sometimes Virtual Console does not get enabled after iDRAC is reset.
Resolution
Toggle the Virtual Console option in the iDRAC web interface.
Versions
/
Systems
Affected