Issue 238583:
Description
On systems with iDRAC8, non-root user privileges are lost after installing and uninstalling a personality module.
Resolution
Login using root credentials and modify the non-root users or reset iDRAC configurations to the default setting.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 203881:
Description
iDRAC interfaces report the battery status as Degraded instead of Battery Missing when the battery is unplugged and
Battery High Temp when the battery temperature exceeds 70°C.
Resolution
None.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and iDRAC8 (PERC8 and PERC9).
Issue 171960:
Description
Lifecycle Controller firmware is inaccessible after a performing hardware diagnostic and rebooting the system. This
issue is captured in the Lifecycle Controller log.
Resolution
Reboot the system again to start Lifecycle Controller.
Versions/Systems Affected
Dell 13th generation of PowerEdge systems with iDRAC8.
Issue 227854:
Description
On certain instances, the communication between iSM and iDRAC fails after enabling or disabling the USB NIC port.
Resolution
Rebooting iDRAC using the racreset command in the RACADM interface.
Versions/Systems Affected:
Dell 13th generation of PowerEdge servers with iDRAC8.
Issue 235870:
Description:
On systems with Emulex NDC, iDRAC may lose connectivity while switching LOMs.
Resolution
Reboot the host operating system or power cycle the chassis to recover.
Versions/Systems Affected:
Dell 12th generation and 13th generation of PowerEdge server with Emulex NDC.