Release Notes
Issue 51:
Description
On the Dell 12th generation PowerEdge servers flashed with iDRAC8, firmware update and configuration operations
including secure erase for Samsung NVMe PCIe SSDs using iDRAC interfaces, do not work. Even though you can
start these tasks using iDRAC interfaces, the tasks will eventually fail.
Resolution
Use other methods of firmware update and configuration using the operating system.
Versions/ Systems Affected
Dell 12th generation PowerEdge systems with iDRAC8.
Issue 52:
Description
Creating T10 PI capable virtual disks using T10 PI capable disk-drives from iDRAC GUI fails.
Resolution
Use RACADM, WS-MAN, or OMSS to create virtual disks with T10 PI capability.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 53:
Description
On the Dell 12th generation PowerEdge systems, when downgrading from 2.10.10 to 1.66.65, existing users may
occasionally be lost.
Resolution
Re-enter the users after the downgrade. It is recommended that you check the custom settings while upgrading or
downgrading the firmware.
Versions/ Systems Affected
All Dell 12th generation PowerEdge systems downgraded from 2.10.10.10 to 1.66.65.
Issue 54:
Description
The watchdog timer expired error is logged in the SEL on deleting an iDRAC license file.
Resolution
None.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC Service Module (iSM) enabled from 1.65.65 to 2.10.10.10.
Issue 55:
Description
When Single Sign-on is enabled, the Apply action intermittently fails on systems running Internet Explorer 10 or later
versions.
Resolution
Retry the apply operation by clicking Apply twice.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.