Release Notes
Resolution
Try any of the following:
Use a local/remote racadm or WS-MAN method to upload the file.
Use a different browser and upload the file.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 47:
Description
The Enumeration filter commands fail for certain filters.
Resolution
Use Enumeration or Get Instance call to view the same data. The required properties can be filtered by the consoles.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 48:
Description
While enumerating using WS-MAN, if you include more than 7 properties in the WQL/CQL query, the select query
does not return any result.
Resolution
The maximum number of properties that can be included in a WQL/CQL query using WS-MAN is 7. Perform the
filtering on the client system or make multiple calls each having not more than 7 properties.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 49:
Description
Scheduling an automatic update using the iDRAC GUI fails in case CSIOR is set to disabled.
Resolution
Use RACADM to schedule an automatic update job with CSIOR disabled or enable CSIOR and update using the
iDRAC GUI.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 50:
Description
The BIOS configuration job completes with errors when Virtualization Technology is set to Enabled or Disabled. All
the settings are successfully applied, however, the job status displays an error.
Resolution
None.
Versions/ Systems Affected
All PowerEdge systems with iDRAC8.