Release Notes

Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 37:
Description
Chassis slots mapped to the server are not visible using the WS-MAN DCIM_Slot class enumeration. DCIM_slot class
provides the server hardware information in terms of available and occupied slots where devices can be added or
removed respectively.
Resolution
None
Versions/ Systems Affected
All Dell Modular PowerEdge systems with iDRAC8.
Issue 38:
Description
While importing or replacing license files using Google Chrome or Microsoft Internet Explorer, the operation fails for
certain license files.
Resolution
Import or replace the license files using other supported browser(s) or using other interfaces such as RACADM,
Lifecycle Controller, and so on.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 39:
Description
When the physical drives connected to a PERC storage controller are in Non-RAID (or unitialized) state, the size
reported by the iDRAC interfaces (WS-MAN, RACADM, and iDRAC GUI) is slightly less than the actual size of the
drive.
Resolution
This is only a reporting issue. Full capacity of the drives can be used to deploy the operating systems. Other Dell
applications and utilities will continue to report the right size.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 40:
Description
On updating Dell PowerEdge FD332 PERC controllers to 25.2.2-0002, the controller is switched to HBA mode.
Resolution
Manually switch the controller to RAID mode by rebooting the host and with the Ctrl+R option using the Option ROM
interface.
Versions/Systems Affected
All Dell PowerEdge system with iDRAC8 and with PERC Controller version 25.2.2-0002.
Issue 41:
Description
The Virtual Address feature under Persistence Policy may not work when set to default, if the
VirtualAddressManagement attribute is set to FlexAddress mode on iDRAC and if the FlexAddress feature is disabled
in CMC.