Release Notes

Resolution
None
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 32:
Description
On the Network Devices page, the Initiator and Storage Target Settings table overflows to the right if you set the
initiator name and chap ID value with more than 120 characters.
Resolution
Reduce the zoom level or use the scrollbar to view the entire data.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 33:
Description
URL string in iDRAC hardware inventory list displays incorrect https port number.
Resolution
IP URL in hardware inventory output always displays the standard https port number, that is, 443.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 34:
Description
Sometimes Virtual Console does not get enabled after iDRAC is reset.
Resolution
Toggle the Virtual Console option in the iDRAC web interface.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 35:
Description
When you update the rebrand image from the iDRAC web interface, the system reboots and the rebranded images are
applied successfully. During POST, if you press <F10>, the Lifecycle Controller UI starts to launch. The progress bar
displays till 90% and then the system starts rebooting.
Resolution
After rebranding, do not access the Lifecycle Controller UI.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 36:
Description
If the number of physical or virtual disks selected for identification is more than 100, the blink or unblink operation
fails without displaying any message.
Resolution
Select less than 100 physical or virtual disks, or the required disk and retry the operation.