Reference Guide
SSNID Type User IP Address Login Date/Time
6 GUI root 192.168.0.10 04/07/2010 12:00:34
Display the details of sessions without header
racadm getssninfo -A
"43584" "SSH" "root" "192.168.0.10" "11/26/2014 18:37:03"
getsvctag
Description
Displays the service tag of the host system.
Synopsis
racadm getsvctag [-m <module>]
Input -m <module> — Must be one of the following values:
• chassis
• server-<n> — where n = 1–16
• server-<nx> — where n = 1–8; x = a, b, c, d (lower case)
• switch-<n> — where n = 1–6
Output Any system tag as applicable.
Example
• Display Service tag of Server in Slot 1
racadm getsvctag -m server-1
• Display Service tag of all the components in the chassis
racadm getsvctag
getsysinfo
Description
Displays information related to iDRAC, managed system, and watchdog conguration.
NOTE: The host name and OS Name elds in the getsysinfo output display accurate information only
if the Dell OpenManage Server Administrator is installed on the managed system. Else, these elds
may be blank or inaccurate. An exception to this are VMware operating system names, which are
displayed even if the Server Administrator is not installed on the managed system.
Synopsis
racadm getsysinfo [-d] [-A] [-c] [-4] [-6]
Input
• —4 — Displays IPv4 settings
• —6 — Displays IPv6 settings
• —c — Displays common settings
• —d — Displays iDRAC information
• —A — Eliminates the printing of headers or labels
Output
RAC Information:
RAC Date/Time = Thu Sep 3 17:25:06 2015
Firmware Version = 2.20.20.20
Firmware Build = 41
Last Firmware Update = 09/02/2015 22:18:35
Hardware Version = 0.01
MAC Address = B8:2A:72:FC:4F:B0
42