Reference Guide
• To export a remote diagnostics report to NFS share:
racadm diagnostics export -f diagnostics -l 192.168.0:/nfs -u
administrator -p xxx
eventlters
Description Displays the list of event lter settings.
To use this subcommand with the set and test option, you must have the Administrator privilege.
Synopsis
racadm eventfilters <eventfilters command type>
racadm eventfilters get -c <alert category>
racadm eventfilters set -c <alert category> -a <action> -n <notifications>
racadm eventfilters set -c <alert category> -a <action> -r <recurrence>
racadm eventfilters test -i <Message ID to test>
NOTE: The general format of an alert category:
idrac.alert.category.[subcategory].[severity]
where, category is mandatory, but subcategory and severity are optional. A severity cannot precede a
subcategory.
Valid Category values are:
• All
• System
• Storage
• Updates
• Audit
• Config
• Worknotes
Valid Severity values are:
• Critical
• Warning
• Info
Valid examples of alert queries are:
• idrac.alert.all
• idrac.alert.audit
• idrac.alert.audit.lic
• idrac.alert.audit.warning
• idrac.alert.audit.lic.critical
Input
• get — Displays the list of eventlter settings.
• set — Congures the actions and notications for a given eventlter conguration.
• -i — Message ID for which the simulation is needed.
• -c — Alert category of the specic event lter.
•
-a — The action that must be invoked when the event occurs. Valid values are none, powercycle,
power off, or systemreset.
• -n — The notication is sent when the event occurs. Valid values are all, snmp, ipmi, ws-events,
oslog, email, remotesyslog or none. You can append multiple notications separated by a comma.
27