System.ThermalSettings.ThirdPartyPCIFanResponse (Read or Write)
Description
Enables or disables the automatic fan speed feature when a third-party PCI card is inserted in the
system.
Legal Values
0 — Disabled
1 — Enabled
Default Value Enabled
Write Privilege Congure iDRAC
License Required Not Applicable
Dependency None
System.ThermalCong
The objects in this group manage the thermal conguration.
System.ThermalCong.CriticalEventGenerationInterval (Read or Write)
Description Indicates the time interval (in days) for critical events to be generated.
Legal Values Integral Values: 0-365
Default Value 30
Write Privilege Congure iDRAC
License Required iDRAC Express or iDRAC Enterprise
Dependency None
System.ThermalCong.EventGenerationInterval (Read or Write)
Description
Indicates the time interval (in days) for warning events to be generated.
Legal Values Integral Values: 0-365
Default Value 30
Write Privilege Congure iDRAC
License Required iDRAC Express or iDRAC Enterprise
Dependency None
System.ThermalCong.FreshAirCompliantConguration (Read Only)
Description
Indicates whether or not the system is congured to be fresh air compliant.
Legal Values
0 — Not Applicable
1 — Yes
2 — No
Default Value 1 — Yes
License Required iDRAC Express or iDRAC Enterprise
Dependency None