Reference Guide
LnkSpeed -- Specifies the port speed used for the selected boot
protocol
Usage -- AutoNeg; 10Mbps Half; 10Mbps Full; 100Mbps Half;
100Mbps Full
Required License -- RACADM
Dependency -- None
NumberVFAdvertised -- The number of PCI Virtual Functions (VFs) to be
advertised on this port in non-NPAR mode.
Usage -- Values from 0 - 256, Default - 0
Required License -- RACADM
Dependency -- VLanMode has to be Enabled
VLanId -- Specifies the ID (tag) for the VLAN Mode. VLAN ID must
be in the range from 0 to 4095
Usage -- Values from 1 - 4095
Required License -- RACADM
Dependency -- VLanMode has to be Enabled
VLanMode -- Virtual LAN mode enables use of a VLAN tag to be used
by [vendor defined boot protocols]
Usage -- Enabled; Disabled
Required License -- RACADM
Dependency -- None
WakeOnLan -- Enables the server to be powered on using an in-band
magic packet
Usage -- Enabled; Disabled
Required License -- RACADM
Dependency -- None
WakeOnLanLnkSpeed -- Select the port speed used for Wake on LAN mode
Usage -- AutoNeg; 10Mbps Half; 10Mbps Full; 100Mbps Half;
100Mbps Full
Required License -- RACADM
Dependency -- None
• To view the help details of attribute level, enter the following command: racadm help <attribute name>
Example:
/tmp # racadm help NIC.NICConfig.WakeOnLanLnkSpeed
WakeOnLanLnkSpeed -- Select the port speed used for Wake on LAN mode
Usage -- AutoNeg; 10Mbps Half; 10Mbps Full; 100Mbps Half; 100Mbps Full
Required License -- RACADM
Dependency -- None/tmp #
• The get and set commands for BIOS and NIC provide the list of attributes on the basis of the system conguration, BIOS
version used, hardware, and so on.
System.Backplane
The objects in this group manage the backplane.
System.Backplane.BackplaneBusMode (Read Only)
Description
Indicates the backplane Serial General Purpose Input or Output (SGPIO) mode.
Legal Values
• 0 — Unknown
• 1 — I2C
• 2 — SGPIO
Default Value 1 — I2C
170