API Guide

Updatable Properties
Parameter Description
PowerLimit updates PowerLimit
Supported Status Codes
HTTP Status Code Extended Information
200 Base.1.0.success
400
Base.1.0.PropertyValueTypeError
Base.1.0.PropertyValueNotInList
Base.1.0.PropertyUnknown
Base.1.0.PropertyNotWritable
Base.1.0.PropertyValueFormatError
500 Base.1.0.InternalError
/redfish/v1/Chassis/<ID>/Power/PowerSupplies/<ID>
Description
Provides details of the power supplies that are associated with the system or device.
Supported HTTP Methods and Privileges
HTTP Method Required Privilege
GET Login
Supported Status Codes
HTTP Status Code
200
400
403
500
/redfish/v1/Chassis/<ID>/Sensors/Voltages/<ID>
Description
Sensor information
Supported HTTP Methods and Privileges
HTTP Method
Required Privilege
GET Login
Supported Status Codes
HTTP Status Code
200
400
500
NOTE: On PowerEdge FX2 systems, iDRAC can display additional instrumentation data from the sensors on the server,
only if the Chassis Monitoring setting is set to enabled on iDRAC and CMC.
28