Release Notes
Issue 252275/253647:
Description
The Fan PWM value displays NA in the iDRAC web and RACADM interface when the host system is powered off.
Resolution
Power on the host system and reboot IDRAC.
Versions/ Systems Affected
Dell PowerEdge R330, PowerEdge R230, PowerEdge T330, PowerEdge T130 with iDRAC8 2.22.22.22
Issue 246466:
Description
The following error message is displayed on the BIOS when 0xA1 IPMI commands fail and the system halts at POST
requiring a key press:
Error message:” UEFI0039: Unable to communicate with iDRAC because of an issue
in the iDRAC Keyboard Controller Style (KCS) Intelligent Platform Management
Interface (IPMI)”.
Resolution
Reset iDRAC to default or perform an LC wipe to fix the issue.
Versions/ Systems Affected
Dell PowerEdge R330, PowerEdge R230, PowerEdge T330, PowerEdge T130 with iDRAC8 2.21.20.21 and
iDRAC8 2.22.22.22
Issue 238683:
Description
The PSU status for cabled PSUs displays OK by default even though iDRAC is unable to query the actual status.
Resolution
None. This is a known limitation for cabled PSU health reporting from iDRAC.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8 2.22.22.22
Issue 257223:
Description
Invalid sensors — CPU1 VRD_3P3_PG and CPU1 VRD 3P3 PG are displayed on the Voltage Sensor page in the
iDRAC web interface.
Resolution
None.
Versions/ Systems Affected
Dell PowerEdge R230, PowerEdge T330, and PowerEdge T130 with iDRAC8 2.22.22.22
I
ssue 256621/256634/256652:
Description
In certain instances, setting virtual MAC addresses for Intel NICs fail.
Resolution
Update the firmware on the Intel NIC to version 17.0.11 or later.
Versions/Systems Affected
Dell 13th generation of PowerEdge servers with iDRAC8.