Release Notes

Resolution
None.
Versions/Systems Affected
Dell PowerEdge M1000e systems
Issue 237790:
Description
On a 12th generation of PowerEdge server with iDRAC7, the firmware version displays iDRAC8 instead of iDRAC7.
Resolution
None.
Versions/Systems Affected
Dell 12th generation of PowerEdge server with iDRAC7
Issue 244737:
Description
DeletVD from CTR-R using warm reboot causes further VD create failure (using iDRAC interfaces through realtime
job) on same physical disks on maxconfig.
Resolution
Perform a power cycle or run the racreset command.
Versions/Systems Affected
All PowerEdge servers that have max configs with more than 2 controllers, greater than 5 enclosures, and over 100+
disks.
Issue 253506:
Description
Creating a RAID 10 volume with span length greater than 2 or number of physical drives more than 8, using any
iDRAC or Lifecycle Controller interfaces such as WS-MAN, RACADM, or web interface results in reduced size VD
creation.
Resolution
Try creating the RAID volume with the above requirements, using <F2> System Setup or Open Manage Server
Administrator.
The fix for this issue is also available in iDRAC8 version 2.21.20.20.
Versions/Systems Affected
All PowerEdge servers that have max configs with more than 2 controllers, greater than 5 enclosures, and over 100+
disks.
Issue 250381:
Description
Querying the RACADM help for invalid BIOS object/group, displays the following error message: error
RAC1021: NIC objects are not available in the current system configuration.
Resolution
Ignore the error message
.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8 2.22.22.22