Release Notes

Resolution
Login using root credentials and modify the non-root users or reset iDRAC configurations to the default setting.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 203881:
Description
iDRAC interfaces report the battery status as Degraded instead of Battery Missing when the battery is unplugged and
Battery High Temp when the battery temperature exceeds 70°C.
Resolution
None.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and iDRAC8 (PERC8 and PERC9).
Issue 171960:
Description
Lifecycle Controller firmware is inaccessible after a performing hardware diagnostic and rebooting the system. This
issue is captured in the Lifecycle Controller log.
Resolution
Reboot the system again to start Lifecycle Controller.
Versions/Systems Affected
Dell 13th generation of PowerEdge systems with iDRAC8.
Issue 227854:
Description
On certain instances, the communication between iSM and iDRAC fails after enabling or disabling the USB NIC port.
Resolution:
Rebooting iDRAC using the racreset command in the RACADM interface.
Versions/Systems Affected:
Dell 13th generation of PowerEdge servers with iDRAC8.
Issue 235870:
Description
On systems with Emulex NDC, iDRAC may lose connectivity while switching LOMs.
Resolution
Reboot the host operating system or power cycle the chassis to recover.
Versions/Systems Affected
Dell 12th generation and 13th generation of PowerEdge server with Emulex NDC.
Issue 245083:
Description
When Direct-attached storage (DAS) drives are inserted or a copyback operation is started on these drives, Lifecycle
Controller logs and other events such as SNMP alerts, syslogs, or email alerts are not generated.