Release Notes

Issue 47:
Description
After importing a server profile, the Input Power Redundant option does not appear under Redundancy Policy on the
Power Configuration page.
Resolution
Reboot iDRAC or perform an AC power cycle to clear the issue.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 48:
Description
Using shortcut key combination on a virtual console using ActiveX displays an error when 2 different iDRAC
interfaces are accessed from the same management station.
Resolution
You can use the mouse to operate the application or use the application menu on the managed station instead of using
the shortcut key combinations.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 49:
Description
Occasionally, uploading the iDRAC files such as license, certificate, firmware, and so on using the iDRAC GUI fails.
Resolution
Try any of the following:
Use a local/remote racadm or WS-MAN method to upload the file.
Use a different browser and upload the file.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 50:
Description
The Enumeration filter commands fail for certain filters.
Resolution
Use Enumeration or Get Instance call to view the same data. The required properties can be filtered by the consoles.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 51:
Description
While enumerating using WS-MAN, if you include more than 7 properties in the WQL/CQL query, the select query
does not return any result.
Resolution
The maximum number of properties that can be included in a WQL/CQL query using WS-MAN is 7. Perform the
filtering on the client system or make multiple calls each having not more than 7 properties.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.