Release Notes

Resolution
This is only a reporting issue. Full capacity of the drives can be used to deploy the operating systems. Other Dell
applications and utilities will continue to report the right size.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 43:
Description
On updating Dell PowerEdge FD332 PERC controllers to 25.2.2-0002, the controller is switched to HBA mode.
Resolution
Manually switch the controller to RAID mode by rebooting the host and with the Ctrl+R option using the Option ROM
interface.
Versions/Systems Affected
All Dell PowerEdge system with iDRAC8 and with PERC Controller version 25.2.2-0002.
Issue 44:
Description
The Virtual Address feature under Persistence Policy may not work when set to default, if the
VirtualAddressManagement attribute is set to FlexAddress mode on iDRAC and if the FlexAddress feature is disabled
in CMC.
Resolution
Set the VirtualAddressManagement attribute to Console mode in iDRAC or enable the FlexAddress feature in CMC.
Versions/ Systems Affected
All Modular Dell PowerEdge systems with iDRAC8.
Issue 45:
Description
While importing the server profile, if the host system experiences an unexpected power loss or if iDRAC resets, the
Import Server Profile operation performs a cleanup and fails.
Resolution
Before you try importing the profile again or performing any other Lifecycle Controller operation, ensure that you run
Collect System Inventory On Reboot (CSIOR). If CSIOR is not enabled, boot in to Lifecycle Controller and exit.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 46:
Description
When setting the plain text password of an account using racadm after it is set with a SHA256 password (using either
XML config or RACADM), the account is disabled.
Resolution
After setting the password with racadm, ensure that you enable the user using either racadm or iDRAC GUI. You can
also set the plain text password in the GUI by selecting the Change Password check box and ensuring that the Enable
User check box is selected.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.