Release Notes
Resolution
Navigate to the Storage > Physical Disks page to view the physical disks that are foreign.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8 and out-of-band enabled PERC storage controllers.
Issue 24:
Description
In the Safari browser, if the iDRAC web session times out; clicking the Virtual Console and logging out of the GUI
page does not work.
Resolution
Instead of Virtual Console menu, choose other options like logout or other menu options, or use GUI refresh or
Browser refresh option to logout.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 25:
Description
After updating the firmware on an enclosure connected to a 12Gbps SAS Controller, the updated firmware version is
not displayed in the inventory or through any of the interfaces (iDRAC GUI, RACADM) until the server is powered off
and then powered back on.
Resolution
Power the server off then power it on. The updated firmware version is displayed.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 26:
Description
Updating multiple iDRAC DUP using the web interface is not successful when the total size of the DUPs exceeds 300
MB.
Resolution
Make sure the total size is less than 300 MB and then perform an update.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 27:
Description
Repository update operations through iDRAC with reserved characters in user name and password may not be
successful at the DUP download stage, even when they are properly percent encoded by the user. This does not affect
other update methods.
Resolution
Use a user name and password without reserved characters and then perform an update.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.