Release Notes

Resolution
The iDRAC can detect the connectivity problem and log a “SYS198” message to the Lifecycle Controller Log. In
addition, the iDRAC will block most operations that would involve or invoke a soft reset. With the exception of the
blocked operations, the iDRAC should function normally, but an AC power cycle must be scheduled as soon as
possible. When in this degraded state, if a blocked operation is attempted, an appropriate error will occur, but may be
different depending on the interface.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 233773:
Description
After applying the Boot Identity profile on the PowerEdge M630 blade server with DX69G NDC card on port 1, the
WWN/MAC page displays the MAC Addresses under the Flexaddress tab only instead of displaying in Remote
assigned MAC Address tab.
Resolution
None.
Versions/Systems Affected
Dell PowerEdge M1000e systems
Issue 237790:
Description
On a 12th generation of PowerEdge server with iDRAC7, the firmware version displays iDRAC8 instead of iDRAC7.
Resolution
None.
Versions/Systems Affected
Dell 12th generation of PowerEdge server with iDRAC7
Issue 244737:
Description
DeletVD from CTR-R using warm reboot causes further VD create failure (using iDRAC interfaces through realtime
job) on same physical disks on maxconfig.
Resolution
Perform a power cycle or run the racreset command.
Versions/Systems Affected
All PowerEdge servers that have max configs with more than 2 controllers, greater than 5 enclosures, and over 100+
disks.
Issue 258250:
Description
You may notice the following issues on the Dell 12th generation of PowerEdge servers with iDRAC connected to the
dedicated network port, if the Evaluation license has expired or after deleting the Enterprise license:
iDRAC web interface fails to switch the NIC Selection option from Dedicated to Shared (default)
the system is inaccessible from remote RACADM and SSH to make changes
the system is blocked