Release Notes

Resolution
Do any of the following:
Disable the Pass all keystrokes to server option.
With Pass all keystrokes to server option enabled, open any menu in the Virtual Console viewer window title
bar, and then re-size the window.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 3:
Description
Relevant error message is not displayed when you apply the Minimum Fan Speed in PWM (% of Max) with custom or
blank value.
Resolution
Enter the value in the range displayed next to the Custom field.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 4:
Description
Relevant error message is not displayed when OS to iDRAC pass-through is disabled or changed to LOM state even if
iDRAC Service Module is installed in the host OS.
Resolution
None.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 5:
Description
Cannot set VNC password with quotes.
Resolution
Do not use double quotes for the VNC password.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 6:
Description
In some scenarios, typically for state change events occurring within a span of few seconds, the sequence of events
reported in the Lifecycle Log (or corresponding SNMP traps) for storage devices may not exactly match the sequence
in which they occurred.
Resolution
Check the current state or attribute of the storage device using any of the iDRAC8 interfaces (example, iDRAC8 web
interface, RACADM, and so on).
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8 and out-of-band enabled PERC storage controllers.