Issue 210079:
Description
While creating virtual disks using iDRAC on Internet Explorer, if you select more than 100 disks an unexpected error
occurs. Maximum number of physical disks that can be selected for RAID 10, 50, and 60 is 256.
Resolution
Use other supported browsers such as Google Chrome or Mozilla Firefox instead of Internet Explorer. You can also try
using other interfaces such as RACADM WS-MAN, OMSS, or PERC CLI tools to create a VD.
Versions/Systems Affected:
All Dell 13th generation of PowerEdge servers.
Issue 239011:
Description:
Email alert is not supported for iDRAC Basic license and it is always enabled on the iDRAC web interface. Disable the
email alert checkboxes for basic management license.
Resolution:
None.
Versions/Systems Affected:
All Dell 13th generation of PowerEdge servers.
Issue 233766:
Description
Peak power and current values in iDRAC8 web GUI may appear abnormally high. Additionally, Lifecycle Controller
logs may generate a false warning entry: “The system board Consumption current is greater
than the upper critical threshold.”
Resolution
None
Versions/Systems Affected
All Dell 12th generation of PowerEdge systems with iDRAC8.
Issue 243960:
Description
On PowerEdge C6320 servers, the Multiple Details field is missing on the Power Monitoring page in the iDRAC web
interface.
Resolution
None
Versions/Systems Affected
Dell PowerEdge C6320 servers
Issue 232174:
Description
WWN/MAC address is not displayed in the iDRAC WWN/MAC page for PowerEdge M830. However, it displays on
the CMC page.
Resolution
None