Reference Guide

encryptvd, enclosures, emms, fans, hotspare, importconfig,
ccheck, secureerase, preparetoremove, blink, unblink,
cancelcheck, init, modifysecuritykey, psus, pdisks,
resetconfig, tempprobes, vdisks, and patrolread.
To create, delete, and secure the virtual disks. To start or stop the consistency check
on the specified virtual disk, run the following command:
racadm storage createvd:<Controller FQDD> -rl {r0|r1|r5|r6|r10|
r50|r60}[-wp {wt|wb|wbf}] [-rp {nra|ra|ara}] [-ss {1k|2k|4k|8k|
16k|32k|64k|128k|256k|512k|1M|2M|4M|8M|16M}]-pdkey:<comma
separated PD FQDD> [-dcp {enabled|disabled|default}] [-name <VD
name>] [-size <VD size>{b|k|m|g|t}] [-T10PIEnable]
racadm storage init:<VD FQDD> -speed {fast|full}
racadm storage deletevd:<VD FQDD>
racadm storage encryptvd:<VD FQDD>
racadm storage createsecuritykey:<Controller FQDD> -key <Key
id> -xxx <passphrase>
racadm storage modifysecuritykey:<Controller FQDD> -key <Key
id>-xxx <old passphrase> -xxx <new passphrase>
racadm storage deletesecuritykey:<Controller FQDD>
racadm storage ccheck:<vdisk fqdd>
racadm storage cancelcheck:<vdisk fqdd>
To convert the physical disk drives and assign or delete a hotspare. To scan physical
disks connected to a controller and detect problem, run the following command:
racadm storage converttononraid:<PD FQDD>
racadm storage converttoraid:<PD FQDD>
racadm storage hotspare:<Physical Disk FQDD> -assign yes -type
dhs -vdkey: <FQDD of VD>
racadm storage hotspare:<Physical Disk FQDD> -assign yes –type
ghs
racadm storage hotspare:<Physical Disk FQDD> -assign no
racadm storage patrolread:<controller FQDD> -state start|stop
NOTE: If the –assign option is no, you cannot add other options. If the
assign
option is yes and if the -type option is not present, the global
hotspare (ghs) is created by default.
To reset, clear, and import the storage configuration to the controller, run the
following command:
racadm storage importconfig:<Controller FQDD>
racadm storage resetconfig:<Controller FQDD>
racadm storage clearconfig:<Controller FQDD>
To start or stop a blink or identify operation on the specified or PCIeSSD device, run
the following command:
racadm storage blink:<FQDD>
racadm storage blink:<PCIeSSD FQDD>
racadm storage unblink:<FQDD>
racadm storage unblink:<PCIeSSD FQDD>
85