Reference Guide
System.ThermalSettings.ThirdPartyPCIFanResponse (Read or Write)
Description
Enables or disables the automatic fan speed feature when a third-party PCI card is
inserted in the system.
Legal Values
• 0 — Disabled
• 1 — Enabled
Default Value Enabled
Write Privilege Configure iDRAC
License Required Not Applicable
Dependency None
System.ThermalConfig
The objects in this group manage the thermal configuration.
System.ThermalConfig.CriticalEventGenerationInterval (Read or Write)
Description
Indicates the time interval (in days) for critical events to be generated.
Legal Values Integral Values: 0-365
Default Value 30
Write
Privilege
Configure iDRAC
License
Required
iDRAC Express or iDRAC Enterprise
Dependency None
System.ThermalConfig.EventGenerationInterval (Read or Write)
Description
Indicates the time interval (in days) for warning events to be generated.
Legal Values Integral Values: 0-365
Default Value 30
Write
Privilege
Configure iDRAC
License
Required
iDRAC Express or iDRAC Enterprise
Dependency None
System.ThermalConfig.FreshAirCompliantConfiguration (Read Only)
Description
Indicates whether or not the system is configured to be fresh air compliant.
Legal Values
• 0 — Not Applicable
221