Reference Guide
This group is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade
Servers.
cfgSensorRedundancyIndex (Read Only)
Description
Specifies index for the sensor redundancy group being read. Only power supply
redundancy is supported.
Legal Values
1
Default
None
cfgSensorRedundancyPolicy (Read or Write)
Description
Sets the power supply redundancy policy.
Legal Values
• 2 — N/A, for systems that are not supported
• 3 — Non Redundant
• 4–1+1 Redundant
• 4–2+1 Redundant
• 16–2+2 Redundant
Default
Any legal value at that particular execution instance.
cfgSensorRedundancyCapabilities (Read Only)
Description
Returns the redundancy capabilities in the form of a bitmask. This bitmask allows the
user to know which values can be set for cfgSensorRedundancyPolicy.
Legal Values
A bit mask. More than 1 bit can be set at a time to indicate multiple redundancy support.
• 0- N/A, for systems that are not supported
• 1- Non-Redundant
• 2- 1+1 — Redundant
• 4- 2+1 — Redundant
• 8- 2+2 — Redundant
Default
0
cfgSensorRedundancyStatus (Read Only)
Description
Indicates the redundancy status. The status is N/A on platforms that do not support the
power supply sensor redundancy.
Legal Values
String:
• N/A
• Full
• Lost
181