Reference Guide

0 (FALSE)
Default
1
cfgRacTuneAsrEnable (Read or Write)
Description Enables or disables iDRAC last crash screen capture feature.
This object property requires an iDRAC reset before it becomes active.
Legal Values
1 (TRUE)
0 (FALSE)
Default
0
cfgRacTuneDaylightOffset (Read Only)
Description
Specifies the daylight savings offset (in minutes) to use for the RAC Time. This value is 0
if the time zone is not a Daylight Saving time zone.
Legal Values
0–60
Default
0
Example
racadm getconfig -g cfgRacTuning [-m server-<n>] -o
<
object name
> <
object value
>
cfgRacTuneRemoteRacadmEnable=1
cfgRacTuneWebserverEnable=1
cfgRacTuneHttpPort=80
cfgRacTuneHttpsPort=443
cfgRacTuneTelnetPort=23
cfgRacTuneSshPort=22
cfgRacTuneIpRangeEnable=0
cfgRacTuneIpRangeAddr=192.168.1.1
cfgRacTuneIpRangeMask=255.255.255.0
# cfgRacTuneTimezoneOffset=-18000
# cfgRacTuneDaylightOffset=3600
cfgRacTuneTimezoneOffset (Read Only)
Description
Specifies the time zone offset (in minutes) from Greenwich Mean Time (GMT) /
Coordinated Universal Time (UTC) to use for the RAC Time. Some common time zone
offsets for time zones in the United States are:
–480 (PST — Pacific Standard Time)
–420 (MST — Mountain Standard Time)
–360 (CST — Central Standard Time)
137