Release Notes

During POST, if the system displays cable detect message: "CBL0001: Backplane 0 power cable
disconnected", you must check all the backplane cables as this message is not limited to Backplane 0 only.
Do not reboot the host while RAID rebuild is in-progress. If the host is reset, IDSDM is also reset.
On certain iDRAC versions, creating vFlash partition and downloading DUP images may take a little longer
than usual due to updated open source packages.
When using Auto Config, the config XML filename must be specified in the DHCP server using the -f
<filename> flag.
iDRAC - Known Issues
Issue 1:
Description
In Chinese locale on Windows operating system, while launching the Virtual Console using Java plug-in, occasionally
you may see a Java compilation error.
Resolution
1. Open the Java control panel.
2. Go to General -> Network Settings.
3. Select Direct Connection and click OK.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 2:
Description
If the management station is using Linux operating system with the Pass all keystrokes to server option enabled, you
cannot resize the Virtual Console viewer window by dragging the corners or frame. This is a limitation of X-Windows.
Resolution
Do any of the following:
Disable the Pass all keystrokes to server option.
With Pass all keystrokes to server option enabled, open any menu in the Virtual Console viewer window title
bar, and then re-size the window.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 3:
Description
Relevant error message is not displayed when you apply the Minimum Fan Speed in PWM (% of Max) with custom or
blank value.
Resolution
Enter the value in the range displayed next to the Custom field.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 4:
Description
Relevant error message is not displayed when OS to iDRAC pass-through is disabled or changed to LOM state even if
iDRAC Service Module is installed in the host OS.