Release Notes
Versions/ Systems Affected
Dell 12th generation PowerEdge systems with iDRAC8.
Issue 57:
Description
The watchdog timer expired error is logged in the SEL on deleting an iDRAC license file.
Resolution
None.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC Service Module (iSM) enabled from 1.65.65 to 2.10.10.10.
Issue 58:
Description
Creating T10 PI capable virtual disks using T10 PI capable disk-drives from iDRAC GUI fails.
Resolution
Use RACADM, WS-MAN, or OMSS to create virtual disks with T10 PI capability.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 59:
Description
On the Dell 12th generation PowerEdge systems, when downgrading from 2.10.10 to 1.66.65, existing users may
occasionally be lost.
Resolution
Re-enter the users after the downgrade. It is recommended that you check the custom settings while upgrading or
downgrading the firmware.
Versions/ Systems Affected
All Dell 12th generation PowerEdge systems downgraded from 2.10.10.10 to 1.66.65.
Issue 60:
Description
iDRAC loses connectivity on Failover NIC.
Resolution
Restart iDRAC.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 61:
Description
When using Auto Config, the following files are not found in the network share:
<ServiceTag>-config.xml
<Model number>-config.xml
config.xml
Resolution
Use the –f <filename> flag to specify the config XML file when configuring the DHCP server.