Release Notes
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 52:
Description
The Enumeration filter commands fail for certain filters.
Resolution
Use Enumeration or Get Instance call to view the same data. The required properties can be filtered by the consoles.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 53:
Description
While enumerating using WS-MAN, if you include more than 7 properties in the WQL/CQL query, the select query
does not return any result.
Resolution
The maximum number of properties that can be included in a WQL/CQL query using WS-MAN is 7. Perform the
filtering on the client system or make multiple calls each having not more than 7 properties.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 54:
Description
Scheduling an automatic update using the iDRAC GUI fails in case CSIOR is set to disabled.
Resolution
Use RACADM to schedule an automatic update job with CSIOR disabled or enable CSIOR and update using the
iDRAC GUI.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 55:
Description
After resetting iDRAC configuration to defaults, the old iDRAC sessions remain active and new users cannot be
created.
Resolution
Reboot iDRAC or perform an AC power cycle to clear the issue.
Versions/ Systems Affected
Dell 12th generation PowerEdge systems with iDRAC8.
Issue 56:
Description
On the Dell 12th generation PowerEdge servers flashed with iDRAC8, firmware update and configuration operations
including secure erase performed using iDRAC interfaces do not work for Samsung NVMe PCIe SSDs. Even though
you can start these tasks using iDRAC interfaces, the tasks will eventually fail.
Resolution
Use other methods of firmware update and configuration using the operating system.