Release Notes
Issue 13:
Description
iDRAC8 user interfaces (example, iDRAC8 web interface, RACADM and so on) does not display the newer storage
enclosure or backplane firmware version when the firmware is updated through the operating system using DUP.
Resolution
To update the storage inventory, perform a server power cycle (cold boot) or reset the iDRAC.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8 and out-of-band enabled PERC storage controllers.
Issue 14:
Description
Power Cap (in Watts, BTU/hr, %) is not accepting values preceding with zero (0).
Resolution
Do not precede a zero (0) while entering value for Power Cap in the Power Configuration page.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 15:
Description
In the Network Interfaces page > Host OS Network Interfaces section, the link to the Network Devices page is not
available for embedded LOM.
Resolution
In the Network Devices page, see the FQDD detail that does not have the link.
Version/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 16:
Description
The Print option in iDRAC web page does not work if you are using Internet Explorer for iDRAC web interface.
Resolution
Use the Print option from the browser or use other supported browsers such as Firefox, Chrome, or MAC Safari.
Version/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 17:
Description
Relevant status is not shown when a corrupt SD card is inserted. Currently, the status is displayed as Absent.
Resolution
Make sure a valid SD card is inserted.
Version/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 18:
Description
When you log in to the iDRAC web interface using Internet Explorer 8.x and prior versions, content in few pages is not
displayed properly and a few UI controls may not work. This is a known issue with Internet Explorer.