Release Notes

LC GUI - Known Issues
Issue 1:
Description
If FlexAddress is enabled on Chassis Management Controllers, iDRAC and Lifecycle Controller do not display the
same MAC addresses.
Resolution
To view the chassis-assigned MAC address, use the iDRAC web interface or the CMC web interface. Go to General->
Network Settings.
Versions/Systems Affected
All LCsupported Dell PowerEdge servers.
Issue 2:
Description
While deploying Windows Server 2008 R2 SP1 from OS Deployment of Lifecycle Controller, installation stops with
the following error:
There is no disk in the drive. Please insert a disk into drive \Device\Harddisk0\DR0.
This issue may occur due to any of the following reasons:
Virtual Media is in the attached state and a media is not mapped.
Virtual Media is in the auto-attached state and a media is not mapped.
Virtual Media being presented by the AVCT SIP and Virtual Media from iDRAC8 in the detached state.
Due to failure to load drivers for RAID controllers on the system.
Note: It does not occur with Virtual Media in the detached state. It also does not occur without the SIP and with Virtual
Media in the detached from iDRAC8.
Resolution
Retry the operation.
Versions/Systems Affected
All LCsupported Dell PowerEdge servers.
Issue 3:
Description
Some of the supported components are not displayed on the Firmware Update-> View Current Versions page.
Resolution
Restart the server and open View Current Versions page.
Versions/Systems Affected
All LCsupported Dell PowerEdge servers.
Issue 4:
Description
If a Mellanox card is present in the system, then under Network Settings, the port number must be displayed as Port 1
and Port 2, because it is a dual port. But, the port number is displayed as Port 1 for both the ports or the port numbers
are not displayed.
Resolution
To distinguish between the port numbers, see the MAC address or the Device Settings.
You can access Device Settings in the following methods:
During POST, press <F2>, and then click System Setup.