Release Notes
• Virtual Media being presented by the AVCT SIP and Virtual Media from iDRAC8 in the detached
state.
• Due to failure to load drivers for RAID controllers on the system.
Note
: It does not occur with Virtual Media in the detached state. It also does not occur without the SIP
and with Virtual Media in the detached from iDRAC8.
Resolution
Retry the operation.
Versions/Systems Affected
All LC–supported Dell PowerEdge servers.
Issue 3:
Description
Some of the supported components are not displayed on the
Firmware Update
->
View Current
Versions
page.
Resolution
Restart the server and open
View Current Versions
page.
Versions/Systems Affected
All LC–supported Dell PowerEdge servers.
Issue 4:
Description
If a Mellanox card is present in the system, then under
Network Settings
, the port number must be
displayed as Port 1 and Port 2, because it is a dual port. But, the port number is displayed as Port 1 for
both the ports or the port numbers are not displayed.
Resolution
To distinguish between the port numbers, see the MAC address or the Device Settings.
You can access Device Settings in the following methods:
• During POST, press <F2>, and then click
System Setup
.
• On the Lifecycle Controller Home page, click System Setup, and then click Advanced Hardware
Configuration.
Versions/Systems Affected
All LC–supported Dell PowerEdge servers
Issue 5:
Description
After you successfully update the firmware of a CPLD on a modular server, and then perform a firmware
update operation of a component that requires a system restart (such as BIOS), the server is automatically
and repeatedly restarted.
Resolution
Perform a Power Cycle operation on the server.
Versions/Systems Affected
All LC–supported Dell PowerEdge servers.