Release Notes
Issue 50:
Description
Using shortcut key combination on a virtual console using ActiveX displays an error when 2 different
iDRAC interfaces are accessed from the same management station.
Resolution
You can use the mouse to operate the application or use the application menu on the managed station
instead of using the shortcut key combinations.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 51:
Description
Occasionally, uploading the iDRAC files such as license, certificate, firmware, and so on using the iDRAC
GUI fails.
Resolution
Try any of the following:
• Use a local/remote racadm or WS-MAN method to upload the file.
• Use a different browser and upload the file.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 52:
Description
The Enumeration filter commands fail for certain filters.
Resolution
Use Enumeration or Get Instance call to view the same data. The required properties can be filtered by
the consoles.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 53:
Description
While enumerating using WS-MAN, if you include more than 7 properties in the WQL/CQL query, the
select query does not return any result.
Resolution
The maximum number of properties that can be included in a WQL/CQL query using WS-MAN is 7.
Perform the filtering on the client system or make multiple calls each having not more than 7 properties.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 54:
Description
Scheduling an automatic update using the iDRAC GUI fails in case CSIOR is set to disabled.
Resolution
Use RACADM to schedule an automatic update job with CSIOR disabled or enable CSIOR and update
using the iDRAC GUI.