Release Notes

Issue 41:
Description
Using the Server Configuration Profile Import feature, changing the virtualization mode and configuring
the partitioned devices fails if the changes are attempted from a single import.
Resolution
Change the virtualization mode to the correct setting in a single import XML job, and then change the
remaining settings using a separate import XML job.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 42:
Description
While importing or replacing license files using Google Chrome or Microsoft Internet Explorer, the
operation fails for certain license files.
Resolution
Import or replace the license files using other supported browser(s) or using other interfaces such as
RACADM, Lifecycle Controller, and so on.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 43:
Description
When the physical drives connected to a PERC storage controller are in Non-RAID (or unitialized) state,
the size reported by the iDRAC interfaces (WS-MAN, RACADM, and iDRAC GUI) is slightly less than the
actual size of the drive.
Resolution
This is only a reporting issue. Full capacity of the drives can be used to deploy the operating systems.
Other Dell applications and utilities will continue to report the right size.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 44:
Description
On updating Dell PowerEdge FD332 PERC controllers to 25.2.2-0002, the controller is switched to HBA
mode.
Resolution
Manually switch the controller to RAID mode by rebooting the host and with the Ctrl+R option using the
Option ROM interface.
Versions/Systems Affected
All Dell PowerEdge system with iDRAC8 and with PERC Controller version 25.2.2-0002.
Issue 45:
Description
The
Virtual Address
feature under
Persistence Policy
may not work when set to default, if the
VirtualAddressManagement attribute is set to FlexAddress mode on iDRAC and if the FlexAddress feature
is disabled in CMC.
Resolution